U2by3W6uaPY

Remote display for APM382 with real-time power readout and data acquisition

This remote display extends the functionality of the Unipower APM382 load monitor, providing a panel-mount interface with serial communication and optional data acquisition.

Stock Code: DSUD382

Minimum Quantity:

ex VAT (%) VAT n/a
From ex VAT (%) VAT n/a Call Free
Discount:
Price ex VAT (%):
VAT n/a:
Due In Due In
Notify when back in stock
Product not available

Remote display and programming unit for APM382

The DSUD382 is a compact remote display designed to interface with the Unipower APM382 motor load monitor. It provides a local LED display and keypad for reading true kW power and configuring parameters. Supplied from the APM382 or an external 15-30 V DC source, it communicates via RS-232C and offers optional data-acquisition memory up to 1 million measurements.

Technical Highlights 🔧

  • Supply voltage: 15-30 V DC, consumption <1 VA.
  • Serial interface: RS-232C (9.6 kbps to APM382, 57.6 kbps to PC).
  • Memory option: up to 1 million measurements with real-time stamp.
  • Panel mounting: 68 x 68 mm cut-out, IP54 front, IP40 housing, operating -15  +50 °C.
  • Indicators: LEDs for power (kW%), set-points, start and reaction timers, limit status and data acquisition.

Benefits ✅

  • Provides a remote display and programming interface, reducing the need to access the APM382 in difficult locations.
  • Optional data acquisition records motor load history for predictive maintenance.
  • Simple serial communication simplifies integration with PLC or SCADA systems.
  • Compact panel-mount housing with IP54 front for industrial environments.

Applications 🚀

  • Pump and conveyor installations where local monitoring of motor load is essential.
  • Remote adjustment of set-points on an APM382 without opening control panels.
  • Integration into data-logging systems via RS-232.

This remote display enhances the functionality of the APM382, offering convenient local indication and programming along with optional data acquisition.

FAQs

  • Q: Can the DSUD382 power itself from the APM382?
    A: Yes, the unit can be supplied directly from the APM382 or from an external 15-30 V DC source.
  • Q: How many measurements can be stored?
    A: The optional data-acquisition module stores up to 1 million time-stamped measurements.
  • Q: What is the mounting cut-out size?
    A: A 68 x 68 mm panel cut-out is required, and the unit provides IP54 protection at the front.
MountingPanel Mount
Size72 x 72
ProtectionIP54