Summary
Radin manufactures the RDS5 range of automatic transfer switches. In a
mains-to-generator panel, the generator provides standby power and the
switch transfers the load once that supply is ready. Charter Controls
supplies the range, including 100 A and 250 A four-pole models.
Meet Radin and the RDS5 range
If you build panels for sites with standby generators, you may see
“mains-to-generator changeover” on a drawing or “ATS” on a parts list.
The first describes the job. The second stands for automatic
transfer switch, the device that changes which source supplies
the load.
Radin makes the RDS5 switches that perform this duty. For a panel builder,
the starting point is the duty on the drawing. For the person looking
after the building, the question is simpler: what happens when the mains
goes off?
What happens when the mains goes off?
-
The mains supply fails. The standby generator takes
time to start and establish a usable supply.
-
The generator becomes available. The ATS can now
transfer the load to the generator without someone having to operate
a manual changeover switch at the panel.
-
The mains returns. Once the normal supply is stable,
the system can transfer the load back according to the panel’s control
sequence.
Explore Radin automatic transfer switches at Charter Controls
The Charter Controls catalogue includes the
100 A Radin RDS5 automatic transfer switch
and the
250 A Radin RDS5 automatic transfer switch.
Both are four-pole, three-position models. Each product page gives the
specification for that particular switch.
For a replacement, use the complete part number from the existing switch
or parts list. For a new panel, have the supply details, required current
rating and pole configuration to hand. If the operator needs to see the
switch position at the panel door or in a building management system,
include that requirement in your enquiry.
Browse the automatic transfer switch range at Charter Controls.
Frequently asked questions
What does an automatic transfer switch do?
An automatic transfer switch (ATS) changes which of two power sources supplies a load. In a standby generator panel, those sources are typically the mains and the generator.
Does the generator supply the load as soon as the mains fails?
The generator needs time to start and establish a usable supply before the ATS can transfer the load. If equipment must remain powered during that interval, the panel specification needs to address how it will be supported.
How do I identify the right Radin RDS5 switch?
Start with the complete part number on the drawing, parts list or existing switch. Compare the current rating, pole configuration and required interfaces with the specification for that model.